1. Others
  2. Others
  3. Cross-linked dextran G 25

Cross-linked dextran G 25 是一种葡聚糖层析介质。Sephadex G-25 分离范围为 1-5 kD (球形蛋白),可用于多肽的分离以及大分子蛋白质的脱盐和缓冲液替换。

MCE 的所有产品仅用作科学研究或药证申报,我们不为任何个人用途提供产品和服务

Cross-linked dextran G 25 Chemical Structure

Cross-linked dextran G 25 Chemical Structure

CAS No. : 9041-35-4

1.  客户无需承担相应的运输费用。

2.  同一机构(单位)同一产品试用装仅限申领一次,同一机构(单位)一年内

     可免费申领三个不同产品的试用装。

3.  试用装只面向终端客户

规格 价格 是否有货 数量
Free Sample (0.1 - 0.2 mg)   Apply now  
100 mg ¥210
In-stock
500 mg ¥420
In-stock
1 g   询价  
5 g   询价  

* Please select Quantity before adding items.

Customer Review

MCE 顾客使用本产品发表的 1 篇科研文献

  • 生物活性

  • 纯度 & 产品资料

  • 参考文献

生物活性

Cross-linked dextran G 25 is a dextran chromatography medium. Sephadex G-25 separates from 1 to 5 kD (spherical proteins) and can be used for the separation of peptides as well as for the desalting and buffer replacement of large molecule proteins[1].

体外研究
(In Vitro)

Guidelines (Following is our recommended protocol. This protocol only provides a guideline, and should be modified according to your specific needs).
1. Swelling: The dry rubber particles need to be swelled for the first time. Place in excess deionized water and swell at room temperature for 3 h, or in a 90°C water bath for 1 h. (forbid to use magnetic stirring during the swelling process to avoid breaking the microspheres)
2. Column packing:
(1) Prepare initial buffer (equilibrium solution) and elution buffer according to the properties of the samples to be separated. In the case of desalting proteins such as proteins, it is generally recommended to use only one buffer with a low salt concentration for sample loading, equilibration and elution in gel chromatography. For example, 50 mM Tris-hydrochloric acid or PBS buffer near neutral; if it is the separation of peptides, 0.15 M NaCl can be appropriately added to shield the interaction between the target and the gel; if it is buffer exchange, select the target buffer as needed.
(2) Drain the gel, prepare a homogenate with initial buffer (at the ratio of gel:buffer = 3:1) and degas.
(3) Fix the column vertically, wet the bottom end with water or buffer and keep the liquid level for a period.
(4) Guide the homogenate with a glass rod and pour it into the column at one time along the inner wall of the column to allow the gel to settle freely in the column, seal the column with water, and settle overnight.
(5) Connect the movable column head at the top of the column, turn on the peristaltic pump, use the operating flow rate to let the buffer flow through 5 times the column volume, and then use 1.5 times the operating flow rate to flow through 5 times the column volume, and adjust the adapter head to make it as close as possible. Finally, equilibrate the column with 2-3 column volumes of buffer.
Note: Air bubbles cannot be introduced during all operations to ensure the uniformity of the gel.
3. Equilibration: Equilibrate the column with the equilibration buffer at the operating flow rate, and observe the change of the detector until the parameters such as conductivity and pH remain unchanged.
4. Loading: switch the switching valve to load the sample, and the sample load is selected according to the nature of the sample and the amount of the chromatography medium. Generally speaking, the sample load does not exceed 25% of the column bed volume. The samples were prepared with equilibration solution and pretreated by filtration with 0.45 μm microporous membrane.
5. Elution: Switch to elution buffer for constant elution, after peaking, to baseline equilibrium.
6. Regeneration: wash with 0.2 mol/L NaOH or non-ionic detergent for 2 times the column volume; then rinse with deionized water for 3-5 times the column volume.
7. Storage: After use, replace the mobile phase with 20% ethanol and store in a refrigerator at 4°C.
8. In order to obtain a better desalination effect, it is recommended to keep the column heights of different particle sizes at: 30 cm and above for coarse particles, 20 cm and above for medium particles, 10 cm and above for fine particles, 5 cm and above for ultra-fine particles, and The smaller the particle size, the higher the resolution and the slower the flow rate.
9. The amount of sample added should be determined according to the experiment. Generally, the maximum sample load does not exceed 30% of the column bed volume, and 10-20% is the best sample load.

MCE has not independently confirmed the accuracy of these methods. They are for reference only.

CAS 号
性状

固体

颜色

White to off-white

运输条件

Room temperature in continental US; may vary elsewhere.

储存方式
Powder -20°C 3 years
4°C 2 years
In solvent -80°C 6 months
-20°C 1 month
纯度 & 产品资料
参考文献

Cross-linked dextran G 25 相关分类

  • 摩尔计算器

  • 稀释计算器

The molarity calculator equation

Mass (g) = Concentration (mol/L) × Volume (L) × Molecular Weight (g/mol)

质量   浓度   体积   分子量 *
= × ×

The dilution calculator equation

Concentration (start) × Volume (start) = Concentration (final) × Volume (final)

This equation is commonly abbreviated as: C1V1 = C2V2

浓度 (start) × 体积 (start) = 浓度 (final) × 体积 (final)
× = ×
C1   V1   C2   V2
Help & FAQs
  • Do most proteins show cross-species activity?

    Species cross-reactivity must be investigated individually for each product. Many human cytokines will produce a nice response in mouse cell lines, and many mouse proteins will show activity on human cells. Other proteins may have a lower specific activity when used in the opposite species.

您最近查看的产品:

Your information is safe with us. * Required Fields.

   产品名称:

 

* 需求量:

* 客户姓名:

 

* Email:

* 电话:

 

* 公司或机构名称:

   留言给我们:

Bulk Inquiry

Inquiry Information

产品名称:
Cross-linked dextran G 25
目录号:
HY-148140
需求量: