1. MCE Kits
  2. Protein Biology
  3. Protein Electrophoresis & WB
  4. Chemiluminescent Detection
  5. Ultra High Sensitivity ECL Kit

Ultra High Sensitivity ECL Kit 

特超敏 ECL 发光液

Cat. No.: HY-K1005
Manual SDS

Ultra High Sensitivity ECL Kit 是基于鲁米诺底物的化学发光试剂盒,用于检测辣根过氧化物酶(HRP)标记的抗体及其关联的抗原。

Ultra High Sensitivity ECL Kit

1.  客户无需承担相应的运输费用。

2.  同一机构(单位)同一产品试用装仅限申领一次,同一机构(单位)一年内

     可免费申领三个不同产品的试用装。

3.  试用装只面向终端客户

规格 价格 是否有货 数量
Free Sample (10 mL)   Apply now  
100 mL ¥530 In-stock
500 mL ¥1900 In-stock

* Please select Quantity before adding items.

注册 MCE会员完成审核
即刻享有 积分商城 300 专属积分

  • Description

  • Storage

  • Protocol

  • Components

  • Documentation

Description
& Advantages

MCE Ultra High Sensitivity ECL Kit enables detection at femtogram range of antigen by oxidizing luminol in the presence of HRP and peroxide. This reaction produces a prolonged chemiluminescence which can be visualized on X-ray film or digital imaging systems. MCE Ultra High Sensitivity ECL Kit produces a strong, long-lived signal, which, combined with very low background levels, allows for long exposure times enabling the detection of low-abundance proteins.

Publications
Storage

Stored at 4°C, and is stable for 1 year.

Protect from light.

Protocol

1   Take MCE Ultra High Sensitivity ECL Kit out of the refrigerator and allow it to equilibrate at room temperature for about 20 minutes.

2   Prepare the ECL working solution.

Note: Approximately 0.1 mL of ECL Reagent is required per cm² of membrane area.

a)   Mix solutions A and B in a 1:1 ratio. Use a in sufficient volume to ensure that the blot is completely wetted with the ECL working solution.

b)   It is recommended to prepare the working solution just before use, although the mixed reagent solution is stable for several hours at room temperature.

3   Place the blot, protein-side up, in a clean container, and add ECL working solution.

4   Incubate the blot for 1-2 minutes at room temperature.

5   Drain the excess substrate and place the blot in a plastic membrane protector. Remove all air bubbles between the blot and the surface of the membrane protector.

6   Visualize the blot using X-ray film or a CCD-based imaging system.

Components
Components HY-K1005-100 mL HY-K1005-500 mL
Solution A 50 mL 50 mL × 5
Solution B 50 mL 50 mL ×5
Documentation
Help & FAQs
  • Do most proteins show cross-species activity?

    Species cross-reactivity must be investigated individually for each product. Many human cytokines will produce a nice response in mouse cell lines, and many mouse proteins will show activity on human cells. Other proteins may have a lower specific activity when used in the opposite species.

您最近查看的产品:

Your information is safe with us. * Required Fields.

   产品名称:

 

* 需求量:

* 客户姓名:

 

* Email:

* 电话:

 

* 公司或机构名称:

   留言给我们:

Bulk Inquiry

Inquiry Information

产品名称:
特超敏 ECL 发光液
目录号:
HY-K1005
需求量: