1. Academic Validation
  2. Pulmonary toxicity studies in rats with triethoxyoctylsilane (OTES)-coated, pigment-grade titanium dioxide particles: bridging studies to predict inhalation hazard

Pulmonary toxicity studies in rats with triethoxyoctylsilane (OTES)-coated, pigment-grade titanium dioxide particles: bridging studies to predict inhalation hazard

  • Exp Lung Res. 2003 Dec;29(8):593-606. doi: 10.1080/01902140390240104.
D B Warheit 1 K L Reed T R Webb
Affiliations

Affiliation

  • 1 DuPont Haskell Laboratory for Health and Environmental Sciences, Newark, Delaware 19714, USA. david.b.warheit@usa.dupont.com
Abstract

The aim of this study was to assess and compare the acute lung toxicities of intratracheally instilled hydrophobic relative to hydrophilic surface-coated titanium dioxide (TiO(2)) particles using a pulmonary bridging methodology. In addition, the results of these instillation studies were bridged with data previously generated from inhalation studies with hydrophilic, pigment-grade (base) TiO(2) particles, using the base, pigment-grade TiO(2) particles as the inhalation/instillation bridge material. To conduct toxicity comparisons, the surface coatings of base pigment-grade TiO(2) particles were made hydrophobic by application of triethoxyoctylsilane (OTES), a commercial product used in plastics applications. For the bioassay experimental design, rats were intratracheally instilled with 2 or 10 mg/kg of the following TiO(2) particle-types: (1) base (hydrophilic) TiO(2) particles; (2) TiO(2) with OTES surface coating; (3) base TiO(2) with Tween 80; or (4) OTES TiO(2) with Tween 80. Saline instilled rats served as controls. Following exposures, the lungs of sham- and TiO(2)-exposed rats were assessed both using bronchoalveolar lavage (BAL) biomarkers and by histopathology of lung tissue at 24 hours, 1 week, 1 month, and 3 months post exposure. The results demonstrated that only the base, high-dose (10 mg/kg) pigment-grade TiO(2) particles and those with particle-types containing Tween 80 produced a transient pulmonary inflammatory response, and this was reversible within 1 week postexposure. The authors conclude that the OTES hydrophobic coating on the pigment-grade TiO(2) particle does not cause significant pulmonary toxicity.

Figures
Products